search:cuff leak相關網頁資料

      • lifeinthefastlane.com
        OVERVIEW The cuff leak test is used to predict risk of post-extubation stridor in intubated patients Use and interpretation of the test needs to take into account the overall context of the patient’s condition and the management implications does not excl
        瀏覽:1107
      • www.ncbi.nlm.nih.gov
        Lung model study To examine the effects of various variables on cuff-leak volume measurement, a two-chamber test lung (Michigan Instruments Inc., Grand Rapids, MI, USA) was used [13]. Each chamber was connected to a common tube representing the trachea ..
        瀏覽:811
    瀏覽:550
    日期:2024-09-13
    Original Article 53 The Role of the Cuff Leak Test in Predicting the Effects of Corticosteroid Treatment on Postextubation Stridor Chih-Liang Wang1, MD; Ying-Huang Tsai1,4, MD; Chung-Chi Huang1,4, MD; Yau-Kwang Wu1, MD; Ming-Zhu Ye2, RT; Hsiu-Min Chou2, R...
    瀏覽:354
    日期:2024-09-12
    Recently, a colleague approached me with a situation that I actually run into fairly regularly, especially with some of the younger RT’s. This colleague, one who is still a fairly ‘young’ RT, told me that one of his intubated patients’ has a cuff leak and...
    瀏覽:1125
    日期:2024-09-13
    1. Intensive Care Med. 2003 Jan;29(1):69-74. Epub 2002 Nov 22. Post-extubation stridor in intensive care unit patients. Risk factors evaluation and importance of the cuff-leak test. Jaber S, Chanques G, Matecki S, Ramonatxo M, Vergne C, Souche B, Perrigau...
    瀏覽:595
    日期:2024-09-11
    32 Critical Care February 2005 Vol 9 No 1 De Backer after deflation of the cuff. Of course, the inspired tidal volume effectively reaching the alveoli will also decrease so that the tidal volume measured with the cuff deflated is influenced by both inspir...
    瀏覽:767
    日期:2024-09-11
    Tuesday March 28, 2006 Cuff leak test - to anticipate post-extubation stridor There are atleast 3 common ways to do cuff leak test to anticipate postextubation stridor but none has been really tested in a big scientific randomized trial. And literature is...
    瀏覽:1123
    日期:2024-09-11
    The cuff-leak test has been proposed as a simple method to predict the occurrence of post-extubation stridor. The test is performed by cuff deflation and measuring the expired tidal volume a few breaths later (VT). The leak is calculated as the difference...
    瀏覽:559
    日期:2024-09-10
    But you cannot go back, and you know something still is not right. What can you do? Table 1 is a guide to assessing endotracheal tube (ETT) function and placement. You are very suspicious of the leak and go through your trouble-shooting list (Table 2). A ...